CONTROL PANELS
Hold Temperature
This setting sets the water temperature for the Hold or Clean state.
Parameter name: HOLD TEMPERATURE
Allowed values: 100˚F to 125˚F or 38˚C to 52˚C
Factory default: 115˚F
Soap Minimum
This is the time setting used to set how long the soap pump will run when the soap usage is
set for the minimum amount.
Parameter name: SOAP MINIMUM
Allowed values: 0:00 to 9.59
Factory default: 0:30
Soap Intermediate
This is the time setting used to set how long the soap pump will run when the soap usage is
set for the intermediate amount.
Parameter name: SOAP INTERMEDIATE
Allowed values: 0:00 to 9.59
Factory default: 0:40
Soap Maximum
This is the time setting used to set how long the soap pump will run when the soap usage is
set for the maximum amount.
Parameter name: SOAP MAXIMUM
Allowed values: 0:00 to 9.59
Factory default: 0:50
Sanitize Soap
This is the time setting used to set how long the sanitize soap pump will run.
Parameter name: SOAP 2 TIME
Allowed values: 0:00 to 9.59
Factory default: 0:00