Technical Manual
Taskmaster
Power Wash Sink System
Model
PP-3
Machine Serial No.
P.O. Box 4149 2674 N. Service Road
Winston Salem, NC 27115-4149 Jordan Station, Ontario, Canada L0R 1S0
336/661-1556 Fax:: 336/661-1660 905/562-4195 Fax: 905/562-4618
www.championindustries.com
Przeglądanie stron 0
1 2 3 4 5 6 ... 66 67

Podsumowanie treści

Strona 1 - Technical Manual

Technical Manual Taskmaster Power Wash Sink System Model PP-3 Machine Serial No. P.O. Box 4149

Strona 2 - Intentionally

OPERATION INSTRUCTIONS Utensils and Silver Ware Utensils and Silver Ware must be placed in a utensil basket. If your unit was not supplied with a ut

Strona 3 - 336/661-1556

OPERATION INSTRUCTIONS Unload Wash Tank The display will indicate that the items are clean when a wash cycle has been completed. At this time the sys

Strona 4 - TABLE OF CONTENTS

OPERATION INSTRUCTIONS 11 NOTES

Strona 5

CONTROL PANELS Control Panels Identifying your control panel There are two types of control panels used, the STANDARD and the DELUXE. Your control b

Strona 6

CONTROL PANELS STANDARD Control Center 115 Mylar Buttons ¾ Temp Button, press to set or display the wash tanks running temperature. When pre

Strona 7 - INITIAL START UP

CONTROL PANELS 14 Mylar Indicator Lights Basic Operation When you first power up to use your wash tank, the display will show fil, fill the wash t

Strona 8 - Approved Chemicals

CONTROL PANELS Advanced Operation Changing Temperature Set Point The temperature set point is the water temperature setting for the wash tank and is

Strona 9 - INSTRUCTIONS

CONTROL PANELS Parameter Mnemonic Parameter Name Description Table 1 Default Value (Celsius) Table 2 Default Value (Fahrenheit) Units sp Setpoint T

Strona 10 - Start the Wash Cycle

CONTROL PANELS Parameter Mnemonic Description Table 1 Default Value (Celsius) Table 2 Default Value (Fahrenheit) Units P 1 Input table 2 10 P 2 Low

Strona 11 -

CONTROL PANELS Display Software Version To display the software version, enter the configuration mode (See instructions listed in the Configuration M

Strona 12 - OPERATION INSTRUCTIONS

Left Blank This Page Intentionally

Strona 13 - Control Panels

CONTROL PANELS Timer Operation The change water timer (t) will retain its current count when the washer is stopped or when power has been disconnecte

Strona 14 - STANDARD Control Center

CONTROL PANELS Wire Diagrams agrams STANDARD – 208VSTANDARD – 208V K1A Z361403GETYPE K THERMOCOUPLE INPUTSOUTPUT 1HEATER- (RED)11910OUTPUT 3SOAP DISP

Strona 15 - Basic Operation

CONTROL PANELS 21 STANDARD – 480V K1A Z361403GETYPE K THERMOCOUPLE INPUTSOUTPUT 1HEATER- (RED)11910OUTPUT 3SOAP DISPENSER+ (YELLOW)+ (YELLOW)Heater

Strona 16 - CONTROL PANELS

CONTROL PANELS 22 Operational Details and Engineering Diagram FIL STATE • Display show fil • Alarm light is on until AL.1 is off •

Strona 17 - Setup Mode Parameter Table

CONTROL PANELS Operation Modes Fill State This mode is entered when the operator drains the water, and as part of the Change Water procedure, a Dr

Strona 18

CONTROL PANELS Drain State When the timer t expires, the controller will change from the RUN STATE to the DRAIN STATE. ¾ Display shows drn ¾ Change

Strona 19

CONTROL PANELS When AL.2 clears, the controller returns to the RUN or STOP STATE. ¾ Display shows the process value ¾ Alarm indicator light is OFF

Strona 20

CONTROL PANELS DELUXE Control Center Champion Display In general, all messages are scrolled in the upper display box at about 2 characters per seco

Strona 21 - K1A Z361403GE

CONTROL PANELS Stop Button A normal press of this key stops the current cycle if one is active. If the unit is currently in the Hold Mode, pressi

Strona 22

CONTROL PANELS Mylar Indicator Lights The soap indicator light will be lit up when the soap pump is on The heater indicator light will be lit up

Strona 23

USER MANUAL Operation & Installation Guide Champion Industries PO Box 4149 Winston Salem, NC 27115 336/661-1556 www.championindustries.com

Strona 24

CONTROL PANELS In the PAUSE state, the wash cycles timer is stopped and the circulation pumps are shut off. The heater is still working to maintain t

Strona 25

CONTROL PANELS The cycle LED will light up and the first setting STEP1 DURATION will scroll on the display, and alternate every 5 seconds with its va

Strona 26 - Trouble Shooting

CONTROL PANELS Step Soap Quantity This setting allows soap quantity control for the step. Setting name: STEP X SOAP QUANTITY Allowed values: MIN,

Strona 27 - Champion

CONTROL PANELS Off State This state is active after filling up the tank with water and pressing the STOP key following the POWER UP state. This is

Strona 28

CONTROL PANELS Hold/Clean State In this state, there is water in the tank, and its temperature is maintained at the Hold Temperature. The pump speed

Strona 29

CONTROL PANELS Soap Level Detection This is an optional feature that your system may not be equipped with. There are 2 inputs that allow connection t

Strona 30 - Change Settings

CONTROL PANELS Auto-Drain / Fill The Auto drain/fill feature is an optional feature and requires extra solenoid valves. Once the Auto-Drain/Fill key

Strona 31 - (46˚ c)

CONTROL PANELS Temperature Probe Error All probes are typically type-K probes. All temperature readings normally associated with a type-K probe are

Strona 32

CONTROL PANELS Omron Inverter Control The Omron Inverter Control inside the DELUXE panel allows for speed control of the 3-phase AC water pumps. For

Strona 33

CONTROL PANELS The parameters that can be changed follow: Temperature Units This setting allows a different temperature unit to be used for display.

Strona 34

TABLE OF CONTENTS NOTES...ERROR! BOOKMARK NOT DEFINED. INITIAL S

Strona 35

CONTROL PANELS Hold Temperature This setting sets the water temperature for the Hold or Clean state. Parameter name: HOLD TEMPERATURE Allowed values:

Strona 36

CONTROL PANELS Sanitize Heater Temperature This setting sets the water temperature for the Sanitize tank. Parameter name: HEATER 2 TEMPERATURE Allowe

Strona 37 - Omron Messages

CONTROL PANELS Dry Fire Threshold This is the maximum allowed temperature that heater sheath can attain. When this is reached, the control assumes t

Strona 38

CONTROL PANELS Operational Details and Engineering Diagram 42 Power-UpstateOff stateTub FillDry-FireCycleprogrammingLow-levelprogrammingWashstateH

Strona 39

CONTROL PANELS 43 Wire Diagrams DELUXE – 208V w/Communications 12341234PORT1+PORT1-PORT2+PORT2-RS-485AC IN531LINE 1GROUNDLINE 2 92141211161567AC OUT

Strona 40

CONTROL PANELS 44 DELUXE – 480V w/Communications 12341234PORT1+PORT1-PORT2+PORT2-RS-485AC IN531LINE 1GROUNDLINE 2 92141211161567AC OUTOUT1-AC (SPDT)

Strona 41

CONTROL PANELS Wash Cycle Defaults Cycle 1 Name English DELICATE WARE CYCLE French LE CYCLE DE MARCHANDISE DELICAT Spanish EL CICLO DELICADO DE WA

Strona 42 - Fill Time

CONTROL PANELS NOTE: See the TIME DISPLAY section shown earlier to view the time format. Cycle 4 Name English POTS AND PANS CYCLE French CYCLE DE POT

Strona 43

CONTROL PANELS 47 NOTES

Strona 44 - Wire Diagrams

INSTALLATION INSTALLATION Pre-Installation ¾ REVIEW – Review all of the instructions prior to installation. ¾ INSTALLATION – Installation should be

Strona 46 - Wash Cycle Defaults

INSTALLATION Plumbing Requirements ¾ WATER SUPPLY – Hot and Cold Water should be supplied by ½” or ¾” water lines, with the ¾” being the preferred me

Strona 47 - TIME DISPLAY

MAINTENANCE WARRANTY INFORMATION Warranty Your pot scrubbing sink is designed and built to deliver many years of trouble free operation. All units ha

Strona 48

MAINTENANCE 51 NOTES

Strona 49 - INSTALLATION

MAINTENANCE 52 MAINTENANCE Routine Maintenance Heater The heating element must be cleaned once every thirty days to ensure maximum heater life. The e

Strona 50 - Electrical Requirements

MAINTENANCE ¾ Carefully pull the heater and wires out, exposing the electrical connections. ¾ Disconnect the electrical Connections. ¾ Remove the g

Strona 51 - WARRANTY INFORMATION

MAINTENANCE ¾ Connect the electrical connection and slide the wires and thermocouple into position. ¾ Install and tighten the clamp. ¾ Install the

Strona 52 - MAINTENANCE

MAINTENANCE 55 ¾ Remove the component plate ¾ Insert the new component plate. ¾ Install the four fasteners to secure the component plate. ¾ Plug i

Strona 53

MAINTENANCE ¾ Remove the old controller and install the new one. ¾ Install the five retainers “C”. ¾ Connect the three plugs “B”. ¾ Connect the f

Strona 54 - Replacing Thermocouple

MAINTENANCE Replacing Soap Pump 57 ¾ Turn off and lockout the incoming power to the control panel. ¾ Disconnect power cord “A” ¾ Disconnect Hoses

Strona 55

PARTS LIST 58 Parts List Heater / Thermocouple Image Description Part Number 2500 watt heater HTR-25 5000 watt heater HTR-50 7000 watt heater HTR

Strona 57 - Replacing Pump

PARTS LIST Soap Pump / STANDARD / DELUXE Image Description Part Number Soap Pump SP-1600 STANDARD 208V Plug-N-Play BoardK1-208 STANDARD 480V Plug-

Strona 58 - Replacing Soap Pump

PARTS LIST Water Pump Image Description Part Number Pump Assembly 208V Left Side PA-208L Pump Assembly 208V Right Side PA-208R Pump Assembly 480V Lef

Strona 59 - Parts List

PARTS LIST Image Description Part Number Pump Backing Plate PBP-01 Pump O-Ring POR-01 Pump Seal PS-01 Pump Discharge Hose – Left Side PDH-L Pu

Strona 60 - PARTS LIST

PARTS LIST 62 NOTES

Strona 61 - Water Pump

PARTS LIST NOTES 63

Strona 62

PARTS LIST NOTES 64

Strona 64

Champion Industries PO Box 4149 Winston Salem, NC 27115 336/661-1556 www.championindustries.com

Strona 65

START UP 6 INITIAL START UP Fill Tanks with Water ¾ WASH TANK – Fill wash tank with hot water to the marked Fill Line. The water temperature ought t

Strona 66

START UP 7 Approved Chemicals It is recommended that chemicals that are low to non foaming, metal safe, and non-caustic be used in the wash and saniti

Strona 67

OPERATION INSTRUCTIONS OPERATION INSTRUCTIONS Pre-Scrapping It is recommended that any loose or excess soils be removed from the item to be washed pr